咨询热线
18566398802Can be used to test the relative resistance to corrosion of components or equipment, when exposed to a changing climate of a salt mist (spray), followed by a high humidity, at an elevated temperature.
Test specimens are placed in an enclosed chamber (a separate salt mist chamber and controlled humidity chamber are generally used), and exposed to a changing climate that comprises of the following 2 part repeating cycle. 2.0 hours exposure to a continuous indirect spray of neutral (pH 6.5 to 7.2) salt water solution, which falls-out on to the specimens at a rate of 1.0 to 2.0ml/80cm²/hour, in a chamber temperature of +15 to+35C. This is followed by either 7 days or 20 to 22 hours (depending on the test severity) exposure to a high humidity climate of 93%RH, in a chamber temperature of +40C. The number of cycle repeats is variable depending on the test severity. One storage period of three days at 21C-25C at 45% - 55%RH is also required
For further information on IEC standards visit; www.iec.ch
Q-fog盐雾试验箱用于IEC 60068-2-52的测试方法